Fluidcontrol
Level switch
Nivotemp NT-EL, NT-ELD
DA100226
12/2021
page 1 / 6
Buhler Technologies LLC, 1030 West Hamlin Road, Rochester Hills, MI 48309
Phone: 248.652.1546, Fax: 248.652.1598
e-mail: sales@buhlertech.com
Internet: www.buhlertech.com
In hydraulics and lubrication technology the fill level of oil tanks
needs to be monitored continuously. Here, modern factory
automation requires compatible signals. Despite central system
control, visualising the current level on the actual tanks is often
desired. To minimise production costs and the space required
on containers, it makes sense to use one monitor for both e.g.
the fill level and oil temperature. The Nivotemp series meets
virtually all requirements arising in this area of application.
NT-EL
NT-EL
Tank connections G1/2, M20x1.5, 7/8-14UNF
M12 plug connection
Level and/or temperature control
Small, compact design
Proven, highly dynamic float system
NT-ELD
NT-ELD
Tank connections G1/2, M20x1.5, 7/8-14UNF
Fixed fill level monitor switching outputs
LED display swivels 270°
Standardised VDMA-based menu structure
Two programmable temperature switching output
Alternatively, one continuous temperature output signal
plus one freely programmable switching output
Switching output configurable as window or hysteresis
Switching output configurable as frequency output (1-100 Hz)
Min./Max. value memory, logbook
Nivotemp NT-EL, NT-ELD
NT-EL Technical Data
Version MS Dimensions given in mm (inch)
Operating pressure: max. 14.5 PSI
min. 50 (2)
L = 280, 370, max. 500 mm (11, 14.6, max. 19.7 in) (in 10 mm / 0.4 in increments)
OD
Seal
(X)
L2 = min. 60 (2.4)
SW27
M12x1
M20x1.5
G1/2
7/8-14 UNF
32 (1.4)
L1 = min. 30 (1.2)
H
Ø18 (0.7)
45 (1.8)
3.5 (0.1)
M20 x1.5
26 (1)
14 (0.6)
Eolastic
seal
G1/2
26.6 (1.05)
14 (0.6)
Eolastic
seal
7/8-14UNF
26 (1)
12.7 (0.5)
O-ring
OD
H
X
Operating temperature: -4 °F to 176 °F
Float: SK 174
Min. fluid density: 0.029 lb/in³
Lengths (all versions): 280, 370, 500 mm (11, 14.6, 19.7 in)
(standard)
variable to max. 500 mm (19.7 in)
Weight at L = 500 mm (19.7 in): approx. 0.4 lb
Material
Float: PU
Immersion tube: Brass
G1/2 connection, M20 x 1,5,7/8-14UNF: Aluminium
Level switching output K40
Number max.: 2 not adjustable
Function: NO / NC*
Max. voltage: 30 V DC
Max. switching current: 0.5 A
Max. contact load: 5 VA
Min. contact spacing: 30 mm (1.2 in)
(in 10 mm / 0.4 in increments)
*NO= falling NC contact / NC = falling NO contact
Optional temperature
Temperature contact: TEL xx
Max. voltage: 30 V DC
Max. switching current: 1 A
Max. contact load: 10 VA
Function: NC
Switching point °F: 122 / 140 / 158 / 176
Switching point tolerance: ± 9 °Ra
Max. hysteresis: 20 ± 9 °Ra
Other temperatures and switching function available upon request
Temperature sensor
Pt100 DIN EN 60 751 (Tolerance ±1.4 °F)
NT-EL default pin assignment
IP rating IP67*
Level contact(s) only
Only level contact K40
and temperature con-
tact (TK)
Level contact K40 and
temperature sensor (PT)
Level contacts K40 and
temperature contact
(TK) with special
connection)
* with IP67 cable box attached
2 Buhler Technologies LLC We reserve the right to amend specification. DA100226 ◦ 12/2021
Nivotemp NT-EL, NT-ELD
Ordering instructions NT-EL
Model key
NT-EL
G1/2
M20
UNF
Brass
MS
Version
Model designation
Connection
Plug
XX
Temperature signal
Pt100
Temperature contact NC contact
TE50NC
TE60NC
TE70NC
TE80NC
= temperature sensor
= 50 °C (122 °F)
= 60 °C (140 °F)
= 70 °C (168 °F)
= 80 °C (176 °F)
M12
Length
280
370
500
variable (please specify)
XX
XX
XX
XX
= G1/2
= M20x1.5
= 7/8-14 UNF
XX
Number of level contacts
1K or 2K (NC / NO)
*
*
max. 1 level contact
Ordering example
You require: Level switch with connector M20x1.5, length L= 370 mm (14.6 in),
2 level contacts, L1 = 280 mm (11 in) NC / L2 = 320 mm (12.6 in) NO
Order NT-EL-MS-M20-M12/370-2K-280NC/320NO
3Buhler Technologies LLCWe reserve the right to amend specification.DA100226 ◦ 12/2021
Nivotemp NT-EL, NT-ELD
Technical Data NT-ELD
Version MS Dimensions given in mm (inch)
Operating pressure: max. 14.5 PSI
min. 50 (2)
OD
Seal
(X)
L2 = min. 60 (2.4)
SW27
M12x1
M20x1.5
G1/2
7/8-14 UNF
14
(0
.6
)
L1 = min. 30 (1.2)
H
Ø18
(0.7)
45 (1.8)
3.5 (0.1)
10°
LEDs
84 (3.3)
14 (0.6)
20.5 (0.8)
40 (1.6)
0.5 (0.01)
24 (0.9)
53 (2.1)
Housing swivels
by min. 270°
L = 280, 370, 500 mm (11, 14.6, 19.7 in) (in 10 mm / 0.4 in increments)
M20 x1.5
26 (1)
14 (0.6)
Eolastic
seal
G1/2
26.9 (1.1)
14 (0.6)
Eolastic-
seal
7/8-14UNF
26 (1)
12.7 (0.5)
O-ring
OD
H
X
Operating temperature: -4 °F to 176 °F
Float: SK 174
Min. fluid density: 0.029 lb/in³
Lengths (all versions): 280, 370, 500 mm (11, 14.6, 19.7 in)
(standard)
variable to max. 500 mm (19.7 in)
Weight at L = 500 mm (19.7 in): approx. 0.7 lb
Material
Float: PU
Immersion tube: Brass
G1/2 connection, M20 x 1,5,7/8-14UNF: Anodised aluminium
Level switching output K40
Number max.: 2 not adjustable
Function: NO / NC*
Max. voltage: 30 V DC
Max. switching current: 0.5 A
Max. contact load: 5 VA
Min. contact spacing: 30 mm (1.2 in)
(in 10 mm / 0.4 in increments)
*NO= falling NC contact / NC = falling NO contact
Temperature display electronics
Display: 4 character 7 segment LED
Operation: Via 3 keys
Memory: Min. / Max. Data memory
Starting current input: approx. 100 mA for 100 ms
Current input during operation: approx. 50 mA (without
current- and switching outputs)
Supply voltage (U
B
): 10–30 V DC (nominal voltage
24 V DC)
Ambient temperature: -4 °F to 158 °F
Temperature display units: °C / °F
Display range: -4 °F to 248 °F
Alarm setting range: 32 °F to 212 °F
Display accuracy: ± 1 % FS
Measuring principle: Pt 100 Class B, DIN EN 60751
4 Buhler Technologies LLC We reserve the right to amend specification. DA100226 ◦ 12/2021
Nivotemp NT-EL, NT-ELD
NT-ELD temperature outputs
Choose from the following switching outputs:
Version 2T 1T-KT
Plug (base): 2 x M12 – 4-pin 2 x M12 – 4-pin
Switching outputs:
2 x freely programmable 1 x freely programmable
Alarm memory: 1 switching output assignable to alarm
logbook
1 switching output assignable to alarm
logbook
max. switching current* 0.5 A per output
continuous short-circuit protected
0.5 A per output
continuous short-circuit protected
Contact load: max. 1 A total max. 1 A total
1 switching output configurable as
frequency output:
0 – 100 Hz
Analogue output: 1 x 4 – 20 mA, 2-10 V DC,
0-10 V DC or 0-5 V DC
Max. burden Ω as current output: = (U
B
-8 V) / 0.02 A
Min. input load min. as voltage output: 10 kΩ
**Output 1 max. 0.2 A.
Ordering instructions NT-ELD
NT-ELD
G1/2
M20
UNF
Brass
MS
Version
Type designation
Connection
Plug
XX
LED temperature display
2T
2 x M12
Length
280 (11 in)
370 (14.6 in)
500 (19.7 in)
variable (please specify)
Number of level contacts
1K or 2K (NC / NO)
XX XX
XX
XX XX XX XX XX XX
Installation dimensions L1 = ...mm
1st level contact
Switching function 1st Contact
NO / NC
Installation dimensions L2 = ...mm
2nd level contact
Switching function 2nd contact
NO / NC
2 x temperature output
1T-KT
1 x temperature output
1 x analogue output
= G1/2
= M20x1.5
= 7/8-14 UNF
Ordering example
You require: Level switch with G1/2 connection, brass, length L= 500 mm (19.7 in), 2 level contacts,
1st contact 100 mm (3.9 in) NC, 2nd contact 450 mm (17.7 in) NO,
temperature analysis with display and 2 programmable outputs.
Order: NT-ELD-MS-G1/2-2M12/500-2K-100NC-450NO-2T
5Buhler Technologies LLCWe reserve the right to amend specification.DA100226 ◦ 12/2021
Nivotemp NT-EL, NT-ELD
NT-ELD standard pin assignment
Plug A level
M12 (base)
Plug B temperature
M12 (base)
Connection schematic:
Number of poles:
4-pin 4-pin
DIN EN:
61076-2-101 61076-2-101
Max. voltage:
30 VDC 30 VDC
IP rating:
IP65 IP65
2T PIN
2 x temperature output
1
2
3
4
+24 V
S2 (PNP)
GND
S1 (PNP)
1T-KT PIN
1 x Temperature output
1 x Analog output
1
2
3
4
+24 V
Analogue
GND
S1 (PNP)
6 Buhler Technologies LLC We reserve the right to amend specification. DA100226 ◦ 12/2021