Nivotemp NT-EL, NT-ELD
Technical Data NT-ELD
Version MS Dimensions given in mm (inch)
Operating pressure: max. 14.5 PSI
min. 50 (2)
OD
Seal
(X)
L2 = min. 60 (2.4)
SW27
M12x1
M20x1.5
G1/2
7/8-14 UNF
14
(0
.6
)
L1 = min. 30 (1.2)
H
Ø18
(0.7)
45 (1.8)
3.5 (0.1)
10°
LEDs
84 (3.3)
14 (0.6)
20.5 (0.8)
40 (1.6)
0.5 (0.01)
24 (0.9)
53 (2.1)
Housing swivels
by min. 270°
L = 280, 370, 500 mm (11, 14.6, 19.7 in) (in 10 mm / 0.4 in increments)
M20 x1.5
26 (1)
14 (0.6)
Eolastic
seal
G1/2
26.9 (1.1)
14 (0.6)
Eolastic-
seal
7/8-14UNF
26 (1)
12.7 (0.5)
O-ring
OD
H
X
Operating temperature: -4 °F to 176 °F
Float: SK 174
Min. fluid density: 0.029 lb/in³
Lengths (all versions): 280, 370, 500 mm (11, 14.6, 19.7 in)
(standard)
variable to max. 500 mm (19.7 in)
Weight at L = 500 mm (19.7 in): approx. 0.7 lb
Material
Float: PU
Immersion tube: Brass
G1/2 connection, M20 x 1,5,7/8-14UNF: Anodised aluminium
Level switching output K40
Number max.: 2 not adjustable
Function: NO / NC*
Max. voltage: 30 V DC
Max. switching current: 0.5 A
Max. contact load: 5 VA
Min. contact spacing: 30 mm (1.2 in)
(in 10 mm / 0.4 in increments)
*NO= falling NC contact / NC = falling NO contact
Temperature display electronics
Display: 4 character 7 segment LED
Operation: Via 3 keys
Memory: Min. / Max. Data memory
Starting current input: approx. 100 mA for 100 ms
Current input during operation: approx. 50 mA (without
current- and switching outputs)
Supply voltage (U
B
): 10–30 V DC (nominal voltage
24 V DC)
Ambient temperature: -4 °F to 158 °F
Temperature display units: °C / °F
Display range: -4 °F to 248 °F
Alarm setting range: 32 °F to 212 °F
Display accuracy: ± 1 % FS
Measuring principle: Pt 100 Class B, DIN EN 60751
4 Buhler Technologies LLC We reserve the right to amend specification. DA100226 ◦ 12/2021